Pole Lift, SLYCMA. Hoistway and car doors, Swinging and automatic doors, Safety devices automatic door, swing door, goods lifts, renovation and modernisation
 
Slycma, doors and equipments for Elevators Ruget Group, global solutions from sheet metal to paint work Pictures gallery of landings and cars doors Our Range of Products and Equipments Download and Print Safety of the Existing Elevators Useful Links Rénolift, cars and equipments for elevators
 
last update :
04/17/2008
 
Laws & Safety
 
 
Other laws :
Afnor
     
   
Safety of existing lifts :
 
We are proposing many components that are able to suit the 74 risks listed in the EN 81-80 SNEL.
For example and for what concerns only the high priority level,
we are able to supply solutions for the following SNEL risks :
SNELL risk list
Hazardous situation
Relevant
clause in
EN 81-80 SNEL
SLYCMA - RENOLIFT
POLE ASCENSEUR PRODUCT
warning vandalism warning explosion    
No or inadequate vandal resistance
 
5.3
  HADES  
               
fingers crushed crush hazard for hands arm broken  
Well enclosures with perforate walls
 
5.5.1.1
  Renolift – Shaft –
Separation with roasting
 
               
crush hazard for hands arm broken danger of falling  
Partially enclosed well with too low enclosure
 
5.5.1.2
  Renolift – Shaft –
Separation with roasting
 
               
arm broken danger of falling warning of poss entrapm  
Inadequate locking devices on access doors to well and pit
 
5.5.2
  GENALOCK  
               
crush hazard for hands arm broken ecrase entre porte  
No or inadequate partitions for several lifts in the same well
 
5.5.6.2
  Renolift – Shaft –
Separation with roasting
 
               
danger of tripping over danger of falling warning of poss entrapm  
Unsafe pit access
 
5.5.8
  Trapdoor for machinery room access  
               
danger of falling ecrase entre porte    
No or inadequate lighting of the well
 
5.5.10
  Shaft lighting RENOLIFT  
         
unguarded sheave gear hazard          
               
danger of tripping over danger of falling    
Inadequate lighting in machine or in pulley room
 
5.6.5
  Shaft lighting RENOLIFT  
         
gear hazard unguarded sheave          
               
fingers crushed crush hazard for hands arm broken  
Perforate landing doors and car doors
 
5.7.1
  PLYCAB and PYL  
               
fingers crushed arm broken danger of falling  
Inadequate glass in doors
 
5.7.3
  ECOSIL, PYL, PLYCAB glazed doors  
               
fingers crushed arm broken closing of automatic doors  
No or inadequate protective devices on power operated doors
 
5.7.6
  Infra red cells  
               
warning vandalism danger of falling    
Unlocking of landing door without a special tool
 
5.7.8.1
  HADES  
               
fingers crushed arm broken danger of falling  
Well enclosure with perforate walls near door locks
 
5.7.8.2
  Separation with roasting  
               
foot crushed falling in the well danger of falling  
Inadequate length of car apron
 
5.8.2
  Retractable toe guard and
large size toe guard
 
               
fingers crushed arm broken warning lift  
Car without doors
 
5.8.3
  Every car doors  
               
arm broken warning falling object danger of falling  
No or inadequate balustrade on car
 
5.8.6
  Balustrade  
               
danger of falling ecrase entre porte arm broken  
Large gap between car and wall facing the car entrance
 
5.11.1
  Locking device between floors  
               
danger of falling ecrase entre porte arm broken  
Excessive distance between car door and landing door
 
5.11.2
  Locking device between floors  
 
 
 
   
   
   
N° SIRET 972 509 210 00050/ RCS Lyon B 972 509 210/ siège social : Parc d'activités Lyon Sud-Ouest - 4 rue du Dôme - BP 49 - 69630 CHAPONOST